* Best Viewed In Internet Explorer
| |
| TSi
Power's Flexible Series UPS is an excellent choice for those
applications that require battery backup with good surge protection, AND
the flexibility of being able to add additional battery cabinets for
extended run-time.
Typical
Applications
UPs-600
is the ideal UPS for computer or telecommunications equipment in
environments where AC power delivery is unreliable and several hours of
battery backup time are necessary.
Key Benefits of
the UPs-600
The
UPs-600 protects connected equipment from: power supply failure,
erroring, system
lockups and re-boots. It contributes to enhanced systems operation,
greater reliability, improved repeatability, and extended operating
life.
Typical back-up time fully loaded is 8 minutes, but 20 minutes can be
obtained when the unit is loaded to 50% of its capacity. Thus, an
application requiring 300VA can be provided with 20 minutes of hold-up. The capability of adding extra EXt-400 external battery packs also
makes this a very cost-effective choice for enabling nearly unlimited
battery backup times. Custom Settings: DIP switches in the rear panel allow the user to set
brownout sensitivity, inverter operating frequency, or alarm mode, for
complete flexibility and control of the UPS.
How the UPs-600
Works
The
UPs-600 continually provides power protection with a capacitive element
and a fast-acting MOV (Metal Oxide Varistor). Upon loss of power, the audible alarm beeps about once a second, as
the battery inverter kicks in within 8ms, which means equipment will
continue to operate without interruption. When the
battery level drops until only a few minutes of holdup time remain, the
alarm will beep, and the LED will flash more rapidly, alerting of
impending shutdown. A DB-9 female connector provides communications capability with
monitoring software which can safely save open files and automatically
shut down your systems.
|
| |
SPECIFICATIONS |
UPs-600 |
| |
Electrical |
|
Capacity in VA (Watts) |
600
VA (400 W) |
| |
UPS type |
Single conversion
standby with 4-8 ms transfer time
|
| |
Input |
| |
Nominal voltage |
120
volts ac, single phase |
| |
Operating voltage |
95
- 135 volts ac. 47~63 Hz, sinusoidal. |
| |
AC input cord |
6
foot long cord w/ NEMA 5-15P plug. |
| |
Output |
| |
Nominal voltage |
120
volts ac, Single Phase |
| |
UPS inverter output |
105 - 130vacRMS, 50 or 60Hz +/-1%
Pulse-width modulated modified square-wave. |
| |
Nominal frequency |
50/60
Hz +/-3 Hz (user-selectable) |
| |
Power efficiency |
98% or higher during ac
operation,
80% or higher during battery inverter operation.
|
| |
Transfer time |
4-
8 ms typical between ac and inverter |
| |
Battery back-up time
(For
more time see below) |
8 minutes @ full load
(400 watts)
20 minutes @ 1/2 load (200 watts)
|
| |
Recharge time |
8
hours to return to 90% capacity after full discharge. |
| |
Optional # EXT-400
Extra
battery pack for
longer back-up time
w/Anderson SB50 connector |
A
matching extra battery cabinet with separate charger, supplying
an additional 45 minutes @ full load, 110 minutes @ half load.
With a weight of 15.9kg (35 lbs), and same size as the UPs-600.
EXt-400’s battery recharge time is 12 hours to 90% capacity. |
| |
Surge protection |
MOV
/ spike surge suppression. |
| |
Surge test conditions |
ANSI/IEEE
C62.41-1991 test pulse,
Category A3, Ring Wave, 6000V, 200A. |
| |
Indicators and alarms |
LED
indicators & audible signals: ac, inverter, & battery status. |
| |
Communications interface |
DB-9
female connector provides communications capability
with optional monitoring or automatic shutdown feature.
|
| |
Ac output receptacles |
Two (NEMA 5-15R) |
| |
Physical |
| |
Dimensions |
125mm(5")wide x
178mm(7")high x 394mm(16")deep
|
| |
Weight |
22
lbs. (9.1 kg.) |
| |
Safety |
| |
Safety standards |
Designed to meet UL
& cUL 1778 standards
|
| |
Safety and reliability |
External fuse protects
all ac circuits.
Internal fuses protect all dc circuits.
Durable, all-steel chassis withstands transport in hostile
environments and operation in any indoor application.
|
| |
Environmental |
| |
Ambient temperature |
0
to +40°C,
90% relative humidity (non-condensing at 25°C) |
| |
Warranty |
| |
Limited Warranty |
Two years, parts and labor. One year on
batteries. |
|
TSi's ongoing product
improvement process makes specifications subject
to change. Other
companies product names herein are for identification purposes only, and
may be trademarks of their respective companies. |
UPs-600 System
Architecture

TSi Power also manufactures
custom UPS. For special applications, please call.
Back To Top
|