| TSi
Power’s Premium Series UPS are constructed with a rugged,
ferroresonant no-break design and a fully isolated sine wave output with
neutral-to-ground bond. This series offers the best surge protection
available, with excellent noise filtering, remote on/off control, and
optional extended battery back-up.
Typical Applications
These heavy-duty UPS
are ideal for backing up critical servers, routers, hubs, networks,
factory/industrial process controls, systems going to export markets,
critical telecom equipment, ISP’s and other areas where reliability is
a must, extended back-up might be necessary, or the power source is
unpredictable.
Key Benefits
This rugged industrial-strength
ferroresonant design reduces the number of solid-state devices required
for power conversion and is suitable for use in severe environments. All
models can be rack-mounted in 19, 23, or 24" racks. Standard
battery run-time is about 30 minutes under typical 50% load. If
additional battery runtime is required, EXt-8000 Battery Extension Units
can be daisy-chained to the UPS unit to provide hours of battery
runtime.
How the
Premium UPs Series Works
The
constant output isolation transformer provides 100% isolation from the
input ac line. The regulated output protects switchmode power supplies
from failure caused by unstable ac mains. The secondary neutral is
bonded to ground, thus eliminating all surge voltages between neutral
and ground. This type of surge protection is superior to all other
technologies and is further enhanced thanks to the built-in low-pass
filter, which takes the edge off even very fast transients.
UPS status is monitored by LED indicators, LED
bar-graph displays and
audible signals for ac status, inverter status, output voltage, load,
and battery status. Alarm interface: Upon loss of power, the audible
alarm will beep. Because the Premium Series is a continuous sine wave ‘no-break’
UPS system, power to equipment loads will be completely unaffected. As
the battery level drops until only a few minutes of holdup time remains,
the audible alarm will change, warning of impending shutdown.
Communications: A DB-9 female connector in the rear panel provides
communications capability with most network operating systems such as
Novell, Unix, Solaris, Windows, Linux, etc. Optional monitoring software
may be needed for some operating systems.
|
| |
SPECIFICATIONS |
UPs-10000 |
UPs-16000 |
UPs-21000 |
| |
Electrical |
|
Capacity in VA (Watts) |
1000VA
(750W) |
1600
VA (1200W) |
2100
VA (1600W) |
| |
Transformer type |
Ferroresonant
constant voltage output isolation transformer |
| |
Isolation |
100%
input/output isolation and output neutral-ground bonding qualifies the UPS output as a "separately derived AC power source" via NEC 250-5D. |
| |
Input |
| |
Nominal voltage |
120
volts ac |
| |
Operating voltage |
90
- 140 Volts without using batteries |
| |
Nominal frequency |
60
Hz sinusoidal +/-5% |
| |
Ac input cord |
6’
line cord (14AWG SJT) with NEMA 5-15P plug |
| |
Output |
| |
Nominal voltage |
120
volts ac +/-3 |
| |
Voltage regulation |
+/-3%
upon changes in line or load |
| |
Crest ratio |
3
: 1 |
| |
Output waveform |
Pure sine wave, less than 3% THD with linear load |
| |
Power efficiency |
90%,
under full load conditions |
| |
Power on/off Switch |
On/off
rocker power switch |
| |
Transfer time |
Zero
(continuous no-break) |
| |
Batteries |
Maintenance
free sealed lead-acid batteries |
| |
Battery backup time |
10
to 15 minutes of backup time at full load
(30 minutes under typical half load) |
| |
Recharge time |
8 hours to return to 90% capacity after full discharge |
| |
Optional # EXT-8000
Extra
battery pack for
longer back-up time
w/Anderson SB50 conn |
A
matching extra battery cabinet with separate charger,
supplying an additional 35 to 45 minutes backup time.
Weight is 32kg (70 lbs), size is the same as the UPs-10000.
EXt-8000’s battery recharge time is 8 hours to 90% capacity. |
| |
Noise filtering |
Low-pass
filter reduces noise over a wide frequency range. |
| |
Surge protection |
A
three-stage surge protection system consisting of
ferroresonant isolation transformer, capacitor & M.O.V. is
included. |
| |
Surge test conditions |
ANSI/IEEE
C62.41-1991 test pulse. Category B3,
Combination Wave, 6000Volts, 3000Amps. |
| |
Surge let-through voltages |
Test
pulse injection: Line-Neutral, Line-Ground & Neutral-Ground.
Combination Wave: L-N: 35V, L-G: 35V, N-G: 0.5V |
| |
Indicators |
‘10
LED’ bar-graph indicators: output voltage, battery voltage,
and shows the output load from 0 to 100% of rated power.
4 status LED’s indicating - AC power present; inverter
status; output mode; AC load, and battery status. |
|
Ac receptacles |
4
NEMA 5-15R |
6
NEMA 5-15R |
6
NEMA 5-15R |
| |
Physical |
|
Dimensions |
431.8 x 533.4 x 127mm
(17"W
x 21"D x 5"H) |
431.8 x 533.4 x 165mm
(17"W
x 21"D x 6.5"H) |
431.8 x 533.4 x 165mm
(17"W
x 21"D x 6.5"H) |
| |
Weight |
31.8 kg (70 lbs) |
49.9 kg (110 lbs) |
59 kg (130 lbs) |
| |
Rack mounting options |
Please
call for factory assistance on rack-mount kit options. |
| |
Safety |
| |
Agency approvals |
Designed
to meet UL, cUL and IEC Safety Standards. |
| |
FET inverter circuit |
FET
inverter circuit ensures efficiency and reliability. |
| |
Environmental |
| |
Ambient temperature |
0°
to +40°C, 90% relative humidity 30-90%, (non-condensing @ 25°C). |
| |
Cooling method |
Forced
air (fan cooled) |
| |
Warranty |
| |
Limited Warranty |
2
years on parts and labor. 1 year on batteries. |
|
TSi's ongoing product
improvement process makes specifications subject to change. Other
companies product names herein are for identification purposes only, and
may be trademarks of their respective companies. |
Premium UPs
Series System Architecture

TSi Power also manufactures
custom uninterruptible power supplies.
For special applications, please call.
Back To Top
|